Log on / register
BioMed Central home | Journals A-Z | Feedback | Support | My details
Open AccessCase report

Independent lung ventilation in a newborn with asymmetric acute lung injury due to respiratory syncytial virus: a case report

Matteo Di Nardo email, Daniela Perrotta email, Francesca Stoppa email, Corrado Cecchetti email, Marco Marano email and Nicola Pirozzi email

Ospedale Pediatrico Bambino Gesu'-IRCS, Rome, Italy

author email corresponding author email

Journal of Medical Case Reports 2008, 2:212doi:10.1186/1752-1947-2-212

Published: 19 June 2008

Abstract

Introduction

Independent lung ventilation is a form of protective ventilation strategy used in adult asymmetric acute lung injury, where the application of conventional mechanical ventilation can produce ventilator-induced lung injury and ventilation-perfusion mismatch. Only a few experiences have been published on the use of independent lung ventilation in newborn patients.

Case presentation

We present a case of independent lung ventilation in a 16-day-old infant of 3.5 kg body weight who had an asymmetric lung injury due to respiratory syncytial virus bronchiolitis. We used independent lung ventilation applying conventional protective pressure controlled ventilation to the less-compromised lung, with a respiratory frequency proportional to the age of the patient, and a pressure controlled high-frequency ventilation to the atelectatic lung. This was done because a single tube conventional ventilation protective strategy would have exposed the less-compromised lung to a high mean airways pressure. The target of independent lung ventilation is to provide adequate gas exchange at a safe mean airways pressure level and to expand the atelectatic lung. Independent lung ventilation was accomplished for 24 hours. Daily chest radiograph and gas exchange were used to evaluate the efficacy of independent lung ventilation. Extubation was performed after 48 hours of conventional single-tube mechanical ventilation following independent lung ventilation.

Conclusion

This case report demonstrates the feasibility of independent lung ventilation with two separate tubes in neonates as a treatment of an asymmetric acute lung injury.


© 1999-2008 Case Reports Ltd unless otherwise stated < info@jmedicalcasereports.com >   Terms and conditions